コンテンツにスキップします

ようこそゲストさん

お願いします ログイン また 登録
製品情報をスキップします

Inclusive Inc

DC電源分布ブロック

$4,820.00

Available: Ships from Manufacturers Warehouse, Special Order, or Made to Order

障害者向けに設計されている場合は、世界税と義務の免除を発送します:あなたの税関の対象となります

アメリカ合衆国:1〜5日、CA / MX 3〜10日、EU 2〜10日、 国際的:7〜10日。
パートナー倉庫からの出荷:3日 - 3週間。予約注文 /オーダーメイド:〜1か月。

空室状況を保存します

✓ ピックアップで利用できます

  • Inclusive Homebase - N Fort Myers Florida

    2145 Cape Way, 33917, North Fort Myers, アメリカ合衆国

    +17637420612

    通常24時間で準備が完了します

  • 障害者によって設計されています
    障害者向け
  • 100%の満足
    保証
  • 最低のコスト配送
    カートで引用

Unlike any other distribution block, uses 6 isolated ports linked, fused, or left open to configure for your application's demands. Two, three, or four battery inputs to two, three, or four fused outputs! Each output has room for two links or Mini-ANL fuses, allowing up to 300A of protection per circuit!

Each port is capable of accepting 0-gauge or 4-gauge power wire, depending on the included tool-less compression fitting used. Now, power for the largest multi-battery installations can easily be routed through one block or even multiple blocks connected in series! Included with this item are your choice of 4 sets of fuses and 2 Mini-ANL Links. 


The KNF-60x4 includes four 1/0 Gauge Fittings, two 4 Gauge Fittings, two MANL-Links and your choice of fuses (selected from the drop down menu above)The KNF60 uses 6 isolated ports in its patent pending design. Each is then linked, fused, or left open to configure the block for your application’s demands. Utilizing three platforms to fuse or link these ports makes the KNF60 unlike any distribution block before it. Each output has room for two links or Mini-ANL fuses allowing up to 240A of protection per circuit!

Each port on the KNF60 is capable of accepting 0 gauge or 4 gauge power cable depending on the fitting used. Now power for the largest installations can be easily be routed through one block!

Dimensions L x W x H: 4.9″ x 4.6″ x 1.85″
Total Ports: 6
Fittings Included: Four 0 Gauge, Two 4 Gauge
Fuse Count: 4 links come with the KNF-60
Fuse Type: Mini-ANL (AFC)
Finish: Black Chrome

Overview – KNF Series Fuse / Distribution Blocks use our compression fittings to secure the input and output cable connections. By changing the fitting type, the installer can select from 1/0 or 4 gauge input or output

Configuration – To setup your four way fuse block, install the Mini-ANL links across the lower center fuse platform, connecting the two center ports together. The two center ports are now your input and “pass through” port. The pass through port can be used to link your front battery to your rear battery(ies) in one seamless connection into the block. Fuses are then inserted from the center ports using the upper and vertical fuse platforms, connecting the upper and lower, left/right output ports.

Please see our compression fittings how to for more information regarding fitting/wire installation here
Download PDF Manual

More notes,

How do I determine what size fuses I need for this fuse block?

Each output of a fuse distribution block normally is connected to a single amplifier. Each amplifier will have either a fuse on board or the manufacture will state within the manual’s installation guide or spec sheet what the max fuse rating or current draw of the amplifier is. If your amp has three 30A fuses on boards, you want a 100A fuse for that particular output of this block (90A is not an option we offer). If the second amp has a single 40A fuse, then a 40A fuse goes into that output of the block and thus a 100A and 40A would be required.

The KNF-60 has many configurations, am I able to change to a different option later?

Yes, the KNF-60 can be reconfigured at any time using additional links or fuses. It is up to the installer to configure the KNF-60 to bet match your installation’s needs.


説明

Unlike any other distribution block, uses 6 isolated ports linked, fused, or left open to configure for your application's demands. Two, three, or four battery inputs to two, three, or four fused outputs! Each output has room for two links or Mini-ANL fuses, allowing up to 300A of protection per circuit!

Each port is capable of accepting 0-gauge or 4-gauge power wire, depending on the included tool-less compression fitting used. Now, power for the largest multi-battery installations can easily be routed through one block or even multiple blocks connected in series! Included with this item are your choice of 4 sets of fuses and 2 Mini-ANL Links. 


The KNF-60x4 includes four 1/0 Gauge Fittings, two 4 Gauge Fittings, two MANL-Links and your choice of fuses (selected from the drop down menu above)The KNF60 uses 6 isolated ports in its patent pending design. Each is then linked, fused, or left open to configure the block for your application’s demands. Utilizing three platforms to fuse or link these ports makes the KNF60 unlike any distribution block before it. Each output has room for two links or Mini-ANL fuses allowing up to 240A of protection per circuit!

Each port on the KNF60 is capable of accepting 0 gauge or 4 gauge power cable depending on the fitting used. Now power for the largest installations can be easily be routed through one block!

Dimensions L x W x H: 4.9″ x 4.6″ x 1.85″
Total Ports: 6
Fittings Included: Four 0 Gauge, Two 4 Gauge
Fuse Count: 4 links come with the KNF-60
Fuse Type: Mini-ANL (AFC)
Finish: Black Chrome

Overview – KNF Series Fuse / Distribution Blocks use our compression fittings to secure the input and output cable connections. By changing the fitting type, the installer can select from 1/0 or 4 gauge input or output

Configuration – To setup your four way fuse block, install the Mini-ANL links across the lower center fuse platform, connecting the two center ports together. The two center ports are now your input and “pass through” port. The pass through port can be used to link your front battery to your rear battery(ies) in one seamless connection into the block. Fuses are then inserted from the center ports using the upper and vertical fuse platforms, connecting the upper and lower, left/right output ports.

Please see our compression fittings how to for more information regarding fitting/wire installation here
Download PDF Manual

More notes,

How do I determine what size fuses I need for this fuse block?

Each output of a fuse distribution block normally is connected to a single amplifier. Each amplifier will have either a fuse on board or the manufacture will state within the manual’s installation guide or spec sheet what the max fuse rating or current draw of the amplifier is. If your amp has three 30A fuses on boards, you want a 100A fuse for that particular output of this block (90A is not an option we offer). If the second amp has a single 40A fuse, then a 40A fuse goes into that output of the block and thus a 100A and 40A would be required.

The KNF-60 has many configurations, am I able to change to a different option later?

Yes, the KNF-60 can be reconfigured at any time using additional links or fuses. It is up to the installer to configure the KNF-60 to bet match your installation’s needs.



選択されたバリアント

0.0 lb

よくある質問

アイテムが発送されたら、注文に関連付けられた電子メールアドレスに追跡情報を送信します。追跡情報を受け取っておらず、2営業日を超えている場合は、(012)123-4567までお問い合わせください。


あなたのカート

あなたのカートは現在空です

あなたのウィッシュリスト